39111 - Thames at Staines

Grid Reference:51 (TQ) 034 713
Operator:EA
Local number:2900
Catchment Area:8120.0 km2
Level of Station:10.0 mOD
Mean flow:55.97 m3s-1
95% exceedance (Q95):  10.5 m3s-1
10% exceedance (Q10):  140.0 m 3s-1
61-90 Av. Ann. Rainfall:  696 mm

Sample Hydrograph of Gauged Daily Flows

Flow Duration Curve for Gauged Daily Flows

Station Description

Ultrasonic gauging station - multi-path (6) in cross configuration; transducers located in piles set in the channel. Excellent agreement between multi-meter check gaugings and US calibration. Levels affected by gate and lock movements. In hot weather temperature gradients can deflect beams. Major PWS abstractions u/s.

Catchment Description

Scarp and vale topography. Diverse geology. Predominantly rural headwaters contrast with substantial urban and suburban development in the lower reaches.

Factors Affecting Runoff

River Flow and Catchment Rainfall on the National River Flow Archive

Gauged Daily Flows (gdf):1990 to 2008
Monthly Catchment Rainfall (rnf):1961 to 2008
                                                         
Datatype1960s1970s1980s1990s2000s
gdf                 
rnf        
                                                          

For many stations monthly peak flows are also archived. When daily flow data are not available monthly mean flows may be held on the National River Flow Archive. See Data Holdings for further information.


NRFA Home Page     Station Summaries     Regional Maps     Data Holdings